{"id":1494,"date":"2026-03-25T18:39:26","date_gmt":"2026-03-25T13:39:26","guid":{"rendered":"https:\/\/danaestrella.kz\/product\/implantable-cardioventricular-defibrillator-single-chamber\/"},"modified":"2026-03-25T18:39:26","modified_gmt":"2026-03-25T13:39:26","slug":"implantable-cardioventricular-defibrillator-single-chamber","status":"publish","type":"product","link":"https:\/\/danaestrella.kz\/en\/product\/implantable-cardioventricular-defibrillator-single-chamber\/","title":{"rendered":"IMPLANTABLE CARDIOVENTRICULAR DEFIBRILLATOR SINGLE-CHAMBER"},"content":{"rendered":"<p>Device: connectors: IS-1, DF-4; weight: 70.7 g.; volume: 68.9 cm3; Dimensions: 74 mm x 54 mm x 9.9 mm.<br \/>\nMaterials in contact with human body tissues: Titanium, polyurethane, silicone rubber<br \/>\nBody shape: Physiological, thin-profile, less than 1 cm thick.<br \/>\nHigh-capacity battery with ENDURALIFE\u2122 technology, providing a service life of more than 17 years.<br \/>\nThe device&#8217;s battery capacity is 1.8 Ah.<br \/>\nThe estimated service life is 17.1 years under the following conditions: VVIR stimulation mode, 15% stimulation, base frequency of 60 per minute, pulse duration of 0.4 ms, electrode impedance of 700 ohms, stimulus amplitude of 2.5 V; accelerometer on; two capacitor charges to maximum energy per year; VEPG recording is always on.<br \/>\nThe device has wireless telemetry and wireless ECG functions.<\/p>\n<p><strong>Features:<\/strong> automatic measurement of stimulation thresholds and automatic adjustment of stimulation parameters when thresholds change.<br \/>\nFrequency adaptation function.<br \/>\nTwo sensors: an accelerometer and a physiological respiratory sensor.<br \/>\nVentricular rate stabilization function.<br \/>\nUp and down rhythm smoothing function, independently programmable. Advanced set of algorithms for the diagnosis and monitoring of heart failure Heart Failure Sensor Suite.<br \/>\nFunction for the diagnosis and monitoring of nocturnal apnea AP Scan.<br \/>\nMaximum programmed shock energy 41 J.<br \/>\nMaximum delivered shock energy 35 J.<br \/>\nMaximum accumulated shock energy 41 J.<br \/>\nStandard capacitor charge time to maximum energy (41 J) at the beginning of service 8.4 sec.<br \/>\nThe maximum number of shocks per episode is 8.<br \/>\nStimulation modes: VVIR; VVI; VOO; OFF.<br \/>\nStimulation parameters. Stimulation amplitude is 0.1 \u2013 7.5 V.<br \/>\nPulse width: 0.1-2.0 ms.<br \/>\nAutomatic measurement of amplitude and adjustment of sensitivity thresholds based on the PZ.<br \/>\nSensitivity: Auto (AGC), 0.15-1.5 mV.<br \/>\nThe polarity of the pancreatic stimulation is integrated bipolar.<br \/>\nMaximum sensory frequency (MSR) \u2013 50-185\/min.<br \/>\nThe maximum stimulation frequency (MPR) is 50-185\/min.<\/p>\n<p><strong>Audio warning signals: <\/strong>during capacitor charge, when the electrode\/device integrity is violated (when the electrode impedance limits are exceeded, when noise appears on the electrode, when the recommended battery replacement time is reached, when the charge time is exceeded at the end of the service life).<br \/>\nThe Heart Failure Sensor Suite diagnostic and monitoring algorithm complex provides multifactorial physiological and individualized clinical data for making more informed decisions in the treatment of patients with heart failure.<br \/>\nThe diagnostic trend function provides an overview of the implanted system and the patient&#8217;s condition over the previous 12 months, with graphs that display long-term clinical trends in the patient&#8217;s condition and the performance of the device and electrodes, such as the frequency of arrhythmias, heart rate, heart rate variability, patient activity, and device-assisted therapy episodes (antitachycardia, defibrillation).<\/p>\n<p><strong>Parameters for detecting tachyarrhythmia:<\/strong><br \/>\nDetection of FJ: detection interval is 240-462 ms.<br \/>\nDetection of fast VT: detection interval is 273-545 ms.<br \/>\nDetection of VT: detection interval is 300-667 ms.<br \/>\nDetection criteria: heart rate (detection interval), regularity, morphology of the QRST complex, algorithms for differentiating ventricular tachycardias from supraventricular tachycardias, stability, and sudden onset.<br \/>\nAntitachycardic stimulation: automatic switching of the ATS before the capacitor is charged (Quick Convert ATP).<br \/>\nTherapy type: Burst; Ramp; Scan; Ramp\/Scan; Off.<br \/>\nNumber of pulses: 1-30.<br \/>\nR-S1 interval =(%RR): 50-97%, step 3%. Minimum interval of ATC V-V 120-400 ms.<br \/>\nTechnology to reduce the number of unjustified shocks AcuShock.<br \/>\nRhythmID and RhythmMatch algorithms for differentiation of FJ \/ FT \/ NJT.<br \/>\nAlgorithm for recognition of electromagnetic noise on the electrode.<br \/>\nAlgorithm for alarm when the electrode is damaged.<br \/>\nBattery technology ENDURALIFE\u2122 with increased capacity increases the service life and possibilities of using the functions and algorithms of the device:<br \/>\nestimated service life is 17.1 years.<\/p>\n<p><strong>Defibrillating electrode: <\/strong>MRI compatible up to 3 T, DF-4 connector, active fixation; presence of a steroid, standard electrode length of 59-64 cm, maximum electrode diameter of 7.3 Fr.<br \/>\nIntroducer: percutaneous, size: 8 Fr<\/p>\n","protected":false},"excerpt":{"rendered":"<p>An MRI-compatible single-chamber implantable cardioverter-defibrillator allows a patient with an implanted system to undergo 1.5 T and 3 T MRI scans without restrictions on the scanning area (including the heart area) or the duration of the MRI scan procedure, provided that the device is implanted with MRI-compatible electrodes and the manufacturer&#8217;s requirements for MRI scans are met.<\/p>\n","protected":false},"featured_media":759,"template":"","meta":{"rs_blank_template":"","rs_page_bg_color":"","slide_template_v7":""},"product_brand":[],"product_cat":[148],"product_tag":[],"class_list":{"0":"post-1494","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-arrhythmology","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/danaestrella.kz\/en\/wp-json\/wp\/v2\/product\/1494","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/danaestrella.kz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/danaestrella.kz\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/danaestrella.kz\/en\/wp-json\/wp\/v2\/media\/759"}],"wp:attachment":[{"href":"https:\/\/danaestrella.kz\/en\/wp-json\/wp\/v2\/media?parent=1494"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/danaestrella.kz\/en\/wp-json\/wp\/v2\/product_brand?post=1494"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/danaestrella.kz\/en\/wp-json\/wp\/v2\/product_cat?post=1494"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/danaestrella.kz\/en\/wp-json\/wp\/v2\/product_tag?post=1494"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}