ELECTROPHYSIOLOGICAL SYSTEM FOR RECORDING INTRACARDIAL SIGNALS LABSYSTEM PRO

Hybrid navigation technology based on magnetic and impedance information – simultaneous creation of an electromagnetic field map using a magnetic sensor and an electric field map containing impedance values that correspond to a coordinate in space.

Category:
Description

LABSYSTEM™ PRO workstation with LS10K computer

  • Intel® Xeon® Processor E-2176G
  • Processor frequency, GHz 4.7
  • RAM, GB 2x8GB DDR4
  • Total memory capacity, TB 2
  • Windows Operating System
  • Disc drive, CD/DVD
  • The presence of a keyboard
  • Optical mouse available
  • Availability of a software and hardware module for capturing X-ray images (frames), PCIe DVI image recording card
  • Color liquid crystal monitor, diagonal size, inch 24
  • Monitor resolution 1920×1200
  • Number of monitors in the hardware room 2
  • Number of monitors in the operating room 2
  • Interfaces for EPT, MAESTRO, Atakr, Atakr II, IBI-1500 T9, IBI-1500 T11, Osypka, STOCKERT, and SMARTABLATE radiofrequency ablators
  • Dimensions: 19.8cm x 42.5cm x 46.5cm
  • Weight: 15 kg
  • Voltage: 220 V, 50-60 Hz

LS Pro WIN7 V2.7 Image Viewer Workstation Software

  • Holter Data Presentation Software – Availability
  • Registration of parameters of radio frequency and cryo exposure – Availability
  • Program for comparing the morphology of the current ECG with the reference ECG, with the output of color overlay and numerical coincidence coefficient
  • Automatic updating of information on the viewing screen when the signal exceeds the specified amplitude – Presence of a trigger
  • Calculation of the average cycle length in atrial fibrillation – Presence of

Clearsign II amplifier for 160 channels

  • ADC resolution, 16 bits
  • Attenuation Factor
  • In-Phase Signal (CMRR), dB >98
  • Number of bipolar intracardial catheter entries, 160
  • “Adjust the sampling frequency of signals for each channel: 1, 2, 4 kHz” Availability
  • Number of recorded surface ECG leads, 12
  • Number of isolated channels for cardiac pacing, units 4
  • Number of catheter modules, units 4
  • Number of intracardial inputs on one catheter module, monopolar 80
  • Band-stop filter, 50 Hz, 60 Hz, adaptive – Availability
  • Number of registered invasive pressure channels, units 4
  • Range of invasive pressure monitoring, mmHg 0-300
  • There are 4 analog inputs
  • 16 analog outputs
  • input resistance of >2.5 MΩ
  • Laser Printer – Availability
  • ELECTROPHYSIOLOGICAL SYSTEM FOR RECORDING INTRACARDIAL SIGNALS