BLAZER ABLATION CATHETER WITH OPEN IRRIGATION
Catheter movement control in two directions: Availability
Catheter diameter: 7.5 Fr
Catheter tip diameter: 7 Fr
Number of poles: 4
Distal electrode length: 4 mm
Distance between electrodes: 2.5 mm
Working length: 110 cm
Open-loop irrigation: Availability
Number of irrigation holes: 6
Dual irrigation chamber: Availability
Electrode operation mode: According to power
Curvature options: Standard (curvature radius of 25mm), or • Large (curvature radius of 33mm),
or • Asymmetric (curvature radius of 17mm and 25mm)
CATHETER ABLATION INTELLANAV STABLEPOINT
Catheter movement control in two directions: Availability
Catheter diameter: 7.5 Fr
Catheter tip diameter: 7 Fr
Number of poles: 4
Distal electrode length: 4 mm
Distance between electrodes: 2.5 mm
Working length: 110 cm
Open-loop irrigation: Availability
Number of irrigation holes: 6
Dual irrigation chamber: Availability
Electric mode: Standard (curvature radius – 25mm), or • Large (curvature radius – 33mm)
CATHETER ABLATION TEMPERATURE BLAZER PRIME HTD
Catheter movement control in two directions: Availability
Catheter diameter: 7 Fr
Catheter tip diameter: 8 Fr
Number of poles: 4
Distal electrode length: 8; 10 mm
Distance between electrodes: 2.5 mm
Working length: 110 cm
Open-loop irrigation: Availability
Number of irrigation holes: 6
Dual irrigation chamber: Availability
Electrode operation mode: According to temperature
Distal part of the high-torque catheter: Presence of
Curvature options: Standard (curvature radius of 25mm), Large (curvature radius of 33mm), or Asymmetric (curvature radius of 17mm and 25mm)
DIAGNOSTIC CONTROLLED CATHETER WITH FIXED VIKING CURVE
Diameter: Fr 5, 6
Number of poles: 10
Electrode material: Platinum, iridium
Available curvature: CS, Josephson, Cournand, Elmhurst, and electrode spacing, mm 2, 5, 2-5-2, 2-8-2
Minimum length: 65, 115 cm
Compatible with 10-pin Boston Scientific cable
ELECTROPHYSIOLOGICAL SYSTEM FOR RECORDING INTRACARDIAL SIGNALS LABSYSTEM PRO
Hybrid navigation technology based on magnetic and impedance information – simultaneous creation of an electromagnetic field map using a magnetic sensor and an electric field map containing impedance values that correspond to a coordinate in space.
FARAPULSE IMPULSE FIELD ABLATION SYSTEM
- Weight kg 110
- Dimensions, length x height x width, cm 79 x 61 x 160
- Input voltage 230 V/50 Hz
- Output voltage, min. kV 1.8
- Output voltage, max. kV 2
- Output voltage step, kV 0.1
- Manual control of the output voltage availability
- Biphase, bipolar signal presence
- Color touch screen availability
- Type of exposure electroporation
HIGH-RESOLUTION MAP CATHETER INTELLAMAP ORION
.Control of catheter movement in two directions: Availability
Variable diameter of the distal end of the catheter (basket-type catheter) for use in various anatomical areas: Availability
Maximum catheter opening diameter: 3.5 cm
IMPLANTABLE CARDIOVENTRICULAR DEFIBRILLATOR SINGLE-CHAMBER
An MRI-compatible single-chamber implantable cardioverter-defibrillator allows a patient with an implanted system to undergo 1.5 T and 3 T MRI scans without restrictions on the scanning area (including the heart area) or the duration of the MRI scan procedure, provided that the device is implanted with MRI-compatible electrodes and the manufacturer’s requirements for MRI scans are met.
IMPLANTED CARDIOVASCULAR DEFIBRILLATOR WITH CARDIORESYNCHRONIZATION THERAPY FUNCTION MRI
Three-chamber device for cardiac resynchronization therapy with cardioversion-defibrillation function (CRT-ICD)
MRI-compatible cardioverter-defibrillator for cardiac resynchronization therapy allows a patient with an implanted system to undergo an MRI scan up to 3 T, without restrictions on the area (including the heart area) and the duration of the MRI scan, provided that the device is implanted with MRI-compatible electrodes and the manufacturer’s requirements for MRI examinations are met.
IMPLANTED CARDIOVENTRICULAR DEFIBRILLATOR TWO-CHAMBER
The MRI-compatible two-chamber implantable cardioverter-defibrillator allows patients with an implanted system to undergo 1.5T and 3T MRI scans without restrictions on the scanning area (including the heart area) or the duration of the MRI scan procedure, provided that the device is implanted with MRI-compatible electrodes and the manufacturer’s requirements for MRI scans are met.
IMPLANTED ELECTROCARDIOSTIMULATOR TWO-CHAMBERED
A dual-chamber implantable pacemaker (IPP) with an extended service life. An MRI-compatible dual-chamber implantable pacemaker allows patients with an implanted system to undergo 1.5T and 3T MRI scans without restrictions on the scanning area (including the heart area) or the duration of the MRI scan procedure, provided that the device is implanted with MRI-compatible electrodes and the manufacturer’s requirements for MRI scans are met.
INTELLAGEN RADIATION ABLATION SYSTEM
INTELLAGEN™ RF generator.
Maximum output power: 100 W
Exposure frequency: 480 ± 1 kHz
Dimensions: 39.9 x 17.8 x 34.4 cm
Weight: 18.5. kg
Number of preset settings: 80